SYNCH=DISABLE__SYNCHRONIZ, INV=NOT_INVERTED, EDGE=NO_EDGE_DETECTION, SELECT=CTOUT_3_OR_T0_MAT3, PULSE=DISABLE_SINGLE_PULSE
Timer 1 CAP1_3 capture input multiplexer (GIMA output 7)
INV | Invert input 0 (NOT_INVERTED): Not inverted. 1 (INPUT_INVERTED): Input inverted. |
EDGE | Enable rising edge detection 0 (NO_EDGE_DETECTION): No edge detection. 1 (RISING_EDGE_DETECTIO): Rising edge detection enabled. |
SYNCH | Enable synchronization 0 (DISABLE__SYNCHRONIZ): Disable synchronization. 1 (ENABLE__SYNCHRONIZA): Enable synchronization. |
PULSE | Enable single pulse generation. 0 (DISABLE_SINGLE_PULSE): Disable single pulse generation. 1 (ENABLE_SINGLE_PULSE): Enable single pulse generation. |
SELECT | Select input. Values 0x3 to 0xF are reserved. 0 (CTOUT_3_OR_T0_MAT3): CTOUT_3 or T0_MAT3 1 (T1_CAP3): T1_CAP3 2 (T0_MAT3): T0_MAT3 |
RESERVED | Reserved |